Author: Mikael Häggström [note 1]

Gross processing in sterilization

In sterilization:[1]

  • Measure length and diameter.
  • Serially section
  • Submit 2 cross sections measuring 5 mm in length.

Communicate to the histology lab to section the specimen as tubular structures, in order to get proper cross-sections.

Microscopic examination in sterilization

Confirm that there is a complete cross-section from each side. Example images of normal vas deferens:

Report

Example report:

Right and left vas deferens segments, excisions:
Complete cross-sections of vasa deferentia without significant histopathologic changes.

Notes