Liver: Difference between revisions

From patholines.org
Jump to navigation Jump to search
Mikael Häggström (talk | contribs)
m Report: Subsectioned
Mikael Häggström (talk | contribs)
m Gross processing: Specified
Line 7: Line 7:
*'''Liver biopsy'''. For a percutaneous liver biopsy, it is recommended to use a Birmingham gauge 16 or wider cutting needle, and obtaining a length of 20–25 mm of liver tissue. The presence of 10–12 portal tracts within the specimen is considered sufficient for reliable analysis, ensuring that architectural relationships between structures are maintained.<ref name="BoydCain2020">{{cite journal|last1=Boyd|first1=Alexander|last2=Cain|first2=Owen|last3=Chauhan|first3=Abhishek|last4=Webb|first4=Gwilym James|title=Medical liver biopsy: background, indications, procedure and histopathology|journal=Frontline Gastroenterology|volume=11|issue=1|year=2020|pages=40–47|issn=2041-4137|doi=10.1136/flgastro-2018-101139}}</ref>
*'''Liver biopsy'''. For a percutaneous liver biopsy, it is recommended to use a Birmingham gauge 16 or wider cutting needle, and obtaining a length of 20–25 mm of liver tissue. The presence of 10–12 portal tracts within the specimen is considered sufficient for reliable analysis, ensuring that architectural relationships between structures are maintained.<ref name="BoydCain2020">{{cite journal|last1=Boyd|first1=Alexander|last2=Cain|first2=Owen|last3=Chauhan|first3=Abhishek|last4=Webb|first4=Gwilym James|title=Medical liver biopsy: background, indications, procedure and histopathology|journal=Frontline Gastroenterology|volume=11|issue=1|year=2020|pages=40–47|issn=2041-4137|doi=10.1136/flgastro-2018-101139}}</ref>


==Gross processing==
==Gross processing in autopsy==
In [[autopsy]], make consecutive liver slices, such as in the sagittal or coronal plane.
Make consecutive liver slices, such as in the sagittal or coronal plane.


===Basic gross examination===
===Basic gross examination===

Revision as of 03:51, 20 December 2019

Author: Mikael Häggström [note 1]

Tissue sampling

  • Autopsy
  • Liver biopsy. For a percutaneous liver biopsy, it is recommended to use a Birmingham gauge 16 or wider cutting needle, and obtaining a length of 20–25 mm of liver tissue. The presence of 10–12 portal tracts within the specimen is considered sufficient for reliable analysis, ensuring that architectural relationships between structures are maintained.[1]

Gross processing in autopsy

Make consecutive liver slices, such as in the sagittal or coronal plane.

Basic gross examination

  • Inspect the color and texture of the surfaces, including external and cut surfaces. Potential pathologies:
  • Look for any focal change in the liver volume, mainly any tumor.
  • Determine liver weight.

Gross report

  • Weight
  • Color and texture of cut surfaces
  • Any focal change

Notes

  1. For a full list of contributors, see article history. Creators of images are attributed at the image description pages, seen by clicking on the images. See Patholines:Authorship for details.

Main page

References

  1. Boyd, Alexander; Cain, Owen; Chauhan, Abhishek; Webb, Gwilym James (2020). "Medical liver biopsy: background, indications, procedure and histopathology ". Frontline Gastroenterology 11 (1): 40–47. doi:10.1136/flgastro-2018-101139. ISSN 2041-4137. 

Image sources